Skip to content

Well-Architected Review

📝 Context

You're conducting a structured review of a customer's workload against established architectural best practices. This is a framework-driven assessment — not freeform critique — that produces a prioritized list of improvements with clear business justification for each.

📋 Pre-Review Checklist

  • [ ] Identify the workload scope — what system or application are you reviewing?
  • [ ] Get architecture diagrams and documentation
  • [ ] Understand the business criticality of the workload
  • [ ] Know who owns the workload 👥 and who will action the findings
  • [ ] Decide which pillars are most relevant (see below)
  • [ ] Schedule 2-4 hours for the review conversation
  • [ ] Prepare pillar-specific questions in advance

🎯 The Six Pillars

The Well-Architected Framework evaluates workloads across six pillars. Not every pillar carries equal weight for every workload — prioritize based on the customer's business context.

%%{init: {'theme': 'neutral', 'themeVariables': {'fontSize': '14px'}}}%%
flowchart TB
    W[Well-Architected workload] --> OE[Operational Excellence]
    W --> S[Security]
    W --> R[Reliability]
    W --> P[Performance Efficiency]
    W --> C[Cost Optimization]
    W --> SU[Sustainability]

    OE -. enables .-> R
    S -. protects .-> R
    P -. shapes .-> C
    C -. constrains .-> SU

1. Operational Excellence

Core question: Can you run this in production without heroics?

Review areas:

  • How are changes deployed? Is there a CI/CD pipeline?
  • What happens when a deployment fails? Can you roll back?
  • How do you detect problems? (Monitoring, alerting, dashboards)
  • Are runbooks documented for common operational tasks?
  • How do you learn from incidents? Is there a postmortem process?
  • What's automated vs. manual? What should be automated but isn't?

Red flags:

  • Deployments that require manual steps beyond "click deploy"
  • No rollback mechanism
  • Alerting that's either silent or so noisy it gets ignored
  • "Only one person knows how to do this"

2. Security

Core question: How do you protect data, systems, and access?

Review areas:

  • Identity and access management — who can do what? How is it enforced?
  • Data protection — encryption at rest and in transit, key management
  • Network security — segmentation, firewall rules, ingress/egress controls
  • Detection — how do you know when something is wrong?
  • Incident response — what happens when a security event occurs?
  • Compliance — what regulatory requirements apply and how are they met?

Red flags:

  • Shared credentials or overly broad IAM policies
  • Unencrypted data stores or connections
  • No network segmentation between workloads
  • Security logs that nobody reviews
  • No incident response plan

3. Reliability

Core question: Does this workload recover from failures automatically?

Review areas:

  • What are the single points of failure?
  • How does the workload handle dependency failures? (retries, circuit breakers, fallbacks)
  • What's the backup strategy? When was the last restore test?
  • How is the workload deployed across failure domains? (AZs, regions)
  • What are the defined SLAs/SLOs? Are they measured?
  • What's the disaster recovery plan? Has it been tested?

Red flags:

  • No multi-AZ deployment for production workloads
  • Backups that have never been tested for restore
  • SLAs defined but not measured
  • No chaos testing or failure injection
  • Single-region deployment for business-critical workloads

4. Performance Efficiency

Core question: Are you using the right resources for the job?

Review areas:

  • Are compute, storage, and database services sized appropriately?
  • Is there caching where it would help? (CDN, application cache, database cache)
  • Are there performance bottlenecks under current or projected load?
  • Is the architecture using managed services where appropriate?
  • Are there opportunities to use serverless or event-driven patterns?
  • How do you load test? When was the last time?

Red flags:

  • Over-provisioned instances running at 5-10% utilization
  • No caching layer for read-heavy workloads
  • Database queries without indexes on common access patterns
  • No load testing before launches or capacity changes
  • Synchronous processing where async would work

5. Cost Optimization

Core question: Are you spending the right amount on the right things?

Review areas:

  • What's the monthly cost? Is it tracked and forecasted?
  • Are there idle or underutilized resources?
  • Are commitment discounts (reserved instances, savings plans) being used?
  • Is there right-sizing automation?
  • Are development and staging environments running 24/7?
  • What's the cost per business transaction or user?

Red flags:

  • No cost visibility at the workload level
  • Development environments running at production scale
  • No use of spot/preemptible instances for fault-tolerant workloads
  • Over-provisioned databases that could use a smaller tier
  • No lifecycle policies on storage (old data staying in hot tiers)

See also: TCO Framework and Cost Optimization

6. Sustainability

Core question: Are you minimizing environmental impact without sacrificing performance?

Review areas:

  • Are workloads running in energy-efficient regions?
  • Is compute right-sized to avoid waste?
  • Are idle resources shut down outside business hours?
  • Is data stored in appropriate tiers based on access frequency?
  • Are you using managed services that benefit from provider-level efficiency?

Red flags:

  • 24/7 resources for 9-5 workloads
  • Redundant data copies without retention policies
  • Over-provisioned infrastructure "just in case"

🎯 Conducting the Review

%%{init: {'theme': 'neutral', 'themeVariables': {'fontSize': '14px'}}}%%
flowchart TD
    A[Scope workload and pillars] --> B[Gather diagrams and evidence]
    B --> C[Facilitate pillar discussion]
    C --> D[Document prioritized findings]
    D --> E[Build improvement plan]
    E --> F[Schedule follow-up review]

Step 1: Scope the review — Pick the workload and agree on which pillars to prioritize. A full six-pillar review takes 4-8 hours of conversation. Start with the 2-3 pillars that matter most to this customer.

Step 2: Gather information — Review diagrams, configs, dashboards, and documentation before the working session. Come with informed questions, not discovery questions.

Step 3: Facilitated discussion — Walk through each pillar with the workload team. Use the questions above as a guide, not a script. The best insights come from follow-up questions when something doesn't quite add up.

Step 4: Document findings — Use the same prioritization from Design Review: 🔴 Critical, 🟡 High, 🟢 Medium, ⚪ Low.

Step 5: Build improvement plan — For each finding, define: what to do, effort estimate, expected impact, and who owns it.

Well-Architected Review Template

Well-Architected Review: [Workload Name]

Date: [Date] Reviewer: [Your name] Workload owner: [Name] Pillars reviewed: [List]

Executive Summary: [2-3 sentences: overall maturity, top risks, key improvements]

Pillar Scores:

PillarMaturityTop FindingPriority
Operational Excellence[Low/Medium/High][Finding][🔴🟡🟢]
Security[Low/Medium/High][Finding][🔴🟡🟢]
Reliability[Low/Medium/High][Finding][🔴🟡🟢]
Performance[Low/Medium/High][Finding][🔴🟡🟢]
Cost[Low/Medium/High][Finding][🔴🟡🟢]
Sustainability[Low/Medium/High][Finding][🔴🟡🟢]

Improvement Plan:

#FindingPillarPriorityEffortOwnerTarget Date
1[Finding][Pillar]🔴[S/M/L][Name][Date]

⚠️ Gotchas

  • Reviewing all six pillars when only two matter — scope to what's relevant
  • Treating it as a checklist instead of a conversation — the value is in the discussion
  • Producing a 50-page report nobody reads — keep findings actionable and prioritized
  • Not connecting findings to business outcomes — "this is a risk" vs. "this could cost you $X in downtime"
  • Running the review without the people who built the system — you need their context
  • One-time review with no follow-up — schedule a re-review in 3-6 months